TIMED REMINDER
– 518 –
A2512-10
To provide an external announcement machine through the COT and DK card:
DESCRIPTION DATA
Assign the Service Restriction Class A for
Timed Reminder to the required stations.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
Allow Timed Reminder in the Service Re-
striction Class A assigned by CM12 Y=02.
(1)
(2)
Y=13
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Assign the access code for Timed Re-
minder set and cancel.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A024: Set
A025: Cancel
Assign the COT card and DK to the re-
quired LEN.
NOTE: The DK card number must be as-
signed to the first LEN (Level 0)
and the third LEN (Level 2) of
each LT slot.
(1)
(2)
000-763: LEN
DB00-DB09: Interface Card No. for Ex-
ternal Announcement
Machine
E800-E831: DK card No.
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
NOTE: Circuit No. 3 of E831 is used
for built-in External Equip-
ment Interface on MP card by
setting CM44.
CM15