TIMED REMINDER
– 519 –
A2512-10
DESCRIPTION DATA
Assign the External Announcement Ma-
chine start function to the DK card.
(1)
(2)
XX Y
XX : 00-31: DK Card No. E800-E831
assigned by CM10
Y : 0-3: Circuit No.
313: MP built-in External Equipment In-
terface
0100: External Announcement Ma-
chine for Timed Reminder Call-
ing
Assign the Timed Reminder feature ac-
cess key to a D
term
, if required.
(1)
(2)
Y=00
My Line No. + + Key No.
F0024
Specify the timing for Timed Reminder
start.
(1)
(2)
228: Timed Reminder start timing
0 : At preset time
1 : Before 5 minutes of preset time
Specify the duration of a Timed Reminder
call.
(1)
(2)
Y=0
23
01-08: 4 sec.-32 sec.
(4 sec. increments)
If no data is set, the default setting is 28-32
sec.
Specify the duration of Message Reply
Timer for Timed Reminder.
(1)
(2)
Y=0
52
01-99: 4 sec.-396 sec.
(4 sec. increments)
If no data is set, the default setting is 60-64
sec.
Specify the number of Timed Reminder
call attempts before abandonment.
(1)
(2)
03
01-15: Number of attempted Timed Re-
minder call
If no data is set, the default setting is 05.
Specify the maximum number of Timed
Reminder calls that can be set at the same
time.
(1)
(2)
04
01-32: Max. number of stations
If no data is set, the default setting is 16.
CM44
A
CM90
CM08
CM41
END