TOLL RESTRICTION-TOTAL DIGIT COUNT
– 525 –
A2523-10
DESCRIPTION DATA
(1)
(2)
Y=04 Answer Signal Condition
00-63: Trunk Route No.
0 : Answer Signal by Meter Pulse
1 : Answer Signal by Polarity Reversal
7 : No answer Signal
In case of no Answer Signal, system recog-
nizes the answer in timing set by CM41
Y=0>03.
(1)
(2)
Y=05 Release Signal Condition
00-63: Trunk Route No.
0 : No Release Signal from C.O.
1 : Release Signal from C.O.
(1)
(2)
Y=08 Dial Pulse Sending
00-63: Trunk Route No.
3 : To send
(1)
(2)
Y=09 Signaling
00-63: Trunk Route No.
15 : Ring Down/Loop Start
(1)
(2)
Y=13
Maximum number of sending digits
00-63: Trunk Route No.
001-254: Maximum number of sending
digits
(1)
(2)
Y=39 Trunk Release by Reverse Signal
from C.O.
00-63: Trunk Route No.
0 : Not released
1 : To release
CM35