UNIFORM CALL DISTRIBUTION (UCD)
– 550 –
A2546-10
To provide the call waiting lamps on the D
term
for Overflowed UCD Call:
DESCRIPTION DATA
Assign the incoming call to queuing mode
when all UCD stations are busy.
(1)
(2)
212
1 : Queuing
Specify the maximum number of queuing
in each UCD group for controlling call wait-
ing lamp of D
term
.
(1)
(2)
15
01-99: Number of queuing in each UCD
group
If no data is set, the default setting is 01.
NOTE: Depending on the number of
queuing station/trunk, lamp indi-
cation pattern on D
term
is differ-
ent as shown below:
N=Number of queuing station/trunk
Assign the Overflowed UCD Call Indica-
tion LED to the required D
term
.
•
(1)
(2)
Y=00
My Line No. + + Key No.
F1280-F1295: UCD Group 0-15
CM42
CM90
START
END
CM08
CONDITIONS LAMP INDICATION
2nd Data=01 Steady on red irrespective of number of queuing station/trunk
1≤N<2nd Data
(2nd Data≠01)
Steady on red
2nd Data≤N
(2nd Data≠01)
Flashing red
,