FEATURES FOR AUSTRALIA ONLY
MFC-INCOMING CALL
– 587 –
A2580-10
DESCRIPTION DATA
Assign the number of received digits of
station number from PSTN.
NOTE: If no data is assigned, the MFC
Signaling can not be provided.
•
(1)
(2)
Y=1
2: Number of received digits of station
number from PSTN
01-31: 1 digit-31 digits
Assign the MFC Sender and Receiver to
each circuit.
NOTE: The first data (AP number 0-3)
corresponds to the AP numbers
(X, Y, Z, W: 04-15, 20-31) as-
signed by CM05, as shown be-
low.
CM31
Y=2 CM05 Y=0
AP number 0: AP number X
AP number 1: AP number Y
AP number 2: AP number Z
AP number 3: AP number W
(X<Y<Z<W)
•
(1)
(2)
Y=2
0-3: AP No.
0 : All circuit are assigned as Sender
1 : Circuit No. 0, 1: Sender
Circuit No. 2, 3: Receiver
2 : Circuit No. 0, 1: Receiver
Circuit No. 2, 3: Sender
3 : All circuits are assigned as Re-
ceiver
END
CM31
A
INITIAL
INITIAL