FEATURES FOR OTHER COUNTRIES ONLY
CALLER ID CLASS
– 601 –
A2594-10
(6) Data Assignment for Multiple CIR Trunk
The development data by CMDC and CMDB are assigned toward the first CIR trunk which has
been assigned a minimum AP number. When providing multiple CIR trunks, save the develop-
ment data and load them for the other CIR trunks according to the following steps.
For detail of MAT operations, refer to the MATWorX User Guide.
STEP 1 After assignment of CMDC and CMDB, save the office data by MAT.
At this time, specify the AREA Number including the MEMORY ADDRESS 00900-
2FFFF.
STEP 2 Set the MB switch to ON (UP) on the first CIR trunk with minimum AP number X.
AP number X< Y< Z< W
STEP 3 As for the second CIR trunk, change the AP number Y to X by CM05 and by the
SENSE switch.
STEP 4 Set the SW1-1 through SW1-4 to ON on the second CIR trunk.
Clear the memory for CMDC and CMDB by CMDB Y=90.
Set the SW1-1 through SW1-4 to OFF on the second CIR trunk.
STEP 5 Load the office data saved in STEP1 by MAT.
STEP 6 As for the second CIR trunk, restore the AP number X to Y by CM05 and by the SENSE
switch.
Jump to STEP17 if no more CIR trunks are provided.
STEP 7 Set the MB switch to ON (UP) on the second CIR trunk with AP number Y.
STEP 8 As for the third CIR trunk, change the AP number Z to X by CM05 and by the SENSE
switch.
STEP 9 Set the SW1-1 through SW1-4 to ON on the third CIR trunk.
Clear the memory for CMDC and CMDB by CMDB Y=90.
Set the SW1-1 through SW1-4 to OFF on the third CIR trunk.
STEP 10 Load the office data saved in STEP1 by MAT.
STEP 11 As for the third CIR trunk, restore the AP number X to Z by CM05 and by the SENSE
switch.
Jump to STEP17 if no more CIR trunks are provided.