ATTENDANT TERMINAL-D
term
– 43 –
A2042-10
DESCRIPTION DATA
Assign each Loop Line number assigned
by CM11 as an Attendant Loop Line.
(1)
(2)
Y=03
AA01-AA75: Loop Line No. assigned
by CM11
08: Attendant Terminal Loop Line
Assign the Service Restriction Class B for
the ICI key to the required ICI/OPR line
numbers assigned by CM11.
NOTE: The Service Restriction Class
number for the Attendant Termi-
nal should be different from an
ordinary station.
(1)
(2)
Y=02
AB00-AB99: ICI/OPR Line No. as-
signed by CM11
XX ZZ
ZZ: 00-15 : Service Restriction Class
B
Allow the ICI/OPE key in the Service Re-
striction Class B assigned by CM12 Y=02.
(1)
(2)
Y=73
00-15: Service Restriction Class B as-
signed by CM12 Y=02
0: ICI/OPE key
Assign a Hot Line station to each ICI/OPR
line number.
With this assignment, each ICI/OPR line is
restricted from call origination.
(1)
(2)
Y=03
AB00-AB99: ICI/OPR No.
04: Hot Line
Assign a UCD station to each ICI/OPR line
number.
With this assignment, ICI/OPR lines are
provided the call queuing facility individu-
ally.
(1)
(2)
(1)
(2)
Y=1
AB00-AB99: ICI/OPR Line No.
1: Pilot station
Y=2
AB00-AB99: ICI/OPR Line No.
00-15: UCD Group No.
NOTE: Individual UCD Group num-
ber must be assigned to each
ICI/OPR line number.
Assign the access code for Priority Call 0
used for Attendant Terminal access.
(1)
(2)
Y= 0-3 Numbering Plan Group 0-3
X-XXXX: Attendant Terminal Access
Code
A088
CM15
CM12
CM12
B
CM17
CM20
A