AUTOMATIC WAKE UP
– 648 –
A2636-10
DESCRIPTION DATA
Assign the access code for Wake Up call
set or reset.
NOTE: This data assignment is not re-
quired when Wake Up is set by
PMS.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A024: Wake Up set from guest
A025: Wake Up cancel from guest
A027: Wake Up set from administrative
station with Single Wake Up
Time operation
NOTE
A028: Wake Up set from administrative
station with Multiple Wake Up
Time operation NOTE
When providing the DAT as the internal
announcement source, assign the access
code to record, replay, and delete a mes-
sage, respectively.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A100: Record
A101: Replay
A102: Delete
Designate the type of tone source for
Wake Up call.
(1)
(2)
Y=1
00: Tone Source of Wake Up Call
XX 00
XX: 00: No Tone
02: External Tone Source
05: Digital Announcement Trunk
14: Hold Tone Source on MP card
15: Internal Tone Generator
When an External Announcement Ma-
chine is required, assign the COT card and
DK card to required LEN.
NOTE: The DK card number must be as-
signed to the first LEN (level 0)
and the third LEN (Level 2) of
each LT slot.
(1)
(2)
000-763: LEN
DB00-DB09: Interface Card No. for Ex-
ternal Announcement
Machine
E800-E831: DK Card No.
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
NOTE: Circuit No. 3 of E831 is used
for built-in External Equip-
ment Interface on MP card by
setting CM44.