-43
Gathering running
-44
Slave error disabling master
-45
End of run activated
-46
Not allowed action due to backlash
-47
Wrong TCL task name: each TCL task name must be different
-48
BaseVelocity must be null
-49
Inconsistent mechanical zero during home search
-50
Motor initialization error: check InitializationAcceleration
-51
Spin value out of range
-52
Group interlock
-53
Not allowed action due to a group interlock
-60
Error during file writing or file doesn't exist
-61
Error during file reading or file doesn't exist
-62
Wrong trajectory element type
-63
Wrong XY trajectory element arc radius
-64
Wrong XY trajectory element sweep angle
-65
Trajectory line element discontinuity error or new element is too small
-66
Trajectory doesn't content any element or not loaded
-68
Velocity on trajectory is too high
-69
Acceleration on trajectory is too high
-70
Final velocity on trajectory is not zero
-71
Error write or read from message queue
-72
Error during trajectory initialization
-73
End of file
-74
Error file parameter key not found
-75
Time delta of trajectory element is negative or null
-80
Event not configured
-81
Action not configured
-82
Event buffer is full
-83
Event ID not defined
-85
Secondary positioner index is too far from first positioner
-90
Focus socket not reseved or closed
-91
Focus event scheduler is busy
-95
Error of executing an optional module
-96
Error of stopping an optional module
-98
Error of unloading an optional module
-99
Fatal external module load: see error.log
-100
Internal error (memory allocation error, …)
-101
Relay Feedback Test failed: No oscillation
-102
Relay Feedback Test failed: Signal too noisy
-103
Relay Feedback Test failed: Signal data not enough for analyse
-104
Error of tuning process initialization
-105
Error of scaling calibration initialization
-106
Wrong user name or password
-107
This function requires to be logged in with Administrator rights
-108
The TCP/IP connection was closed by an administrator
-109
Group need to be homed at least once to use this function (distance
mesured during home search)
EDH0373En1023 — 01/18 684

Table of Contents

Other manuals for Newport XPS-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Newport XPS-D and is the answer not in the manual?

Newport XPS-D Specifications

General IconGeneral
BrandNewport
ModelXPS-D
CategoryController
LanguageEnglish

Related product manuals