XPS Unified Programmer’s Manual
-110
Execution not allowed for Gantry configuration
-111
Gathering buffer is full
-112
Error of excitation signal generation initialization
-113
Both ends of run activated
-114
Clamping timeout
-115
Function is not supported by current hardware
-116
Error during external driver initialization, read error.log file for more
details
-117
Function is only allowed in DISABLED group state
-118
Not allowed action driver not initialized
-119
Position is outside of travel limits on secondary positioner
-120
Warning following error during move with position compare enabled
-121
Function is not allowed due to configuration disabled
-122
Data incorrect (wrong value, wrong format, wrong order or inexistent)
-123
Action not allowed, an Administrator is already logged in
-124
Error during move of secondary positioner: check positioners errors
for details
-125
Check tcl task name is not empty
-126
Wrong parameter type in the command string: short or short *
expected
-127
Wrong parameter type in the command string: long or long * expected
-128
Wrong parameter type in the command string: unsigned short or
unsigned short * expected
-129
Wrong parameter type in the command string: unsigned long or
unsigned long * expected
-130
Wrong parameter type in the command string: float or float * expected
-131
Wrong parameter type in the command string: long long int or long
long int * expected
-132
Wrong parameter type in the command string: unsigned long long or
unsigned long long * expected
-133
Error when creating actions tasks
-134
Changing the loop status is allowed in DISABLE state only
-135
Function is not allowed because group is not initialized or not
referenced
-136
Wrong parameter type in the command string: charhex32 * expected
-137
Event&Action: action threads number exceeds limit (must be ≤20)
-138
Event&Action: action thread is running
-139
Event&Action: Always event is not compatible with associated action
-200
Invalid socket
-201
The group is already in this mode
-202
Not allowed action due to an external motion interlock
-204
Function is not allowed because the feed forward is enabled
-205
Not enable in your configuration
-206
Dual encoder position error
-207
Gantry mode error: check Encoder Matrix and Decoupling Motor
Matrix
-208
Not allowed action because piston is engaged
-209
INT board command failed: invalid card number or initialization not
done
-210
Not allowed action due to (XStart ≤Xangle ≤XEnd) is not true
685 EDH0373En1023 01/18