Control System 61Service Manual – CS7000
• 15 or 16 Service Menu
– 1 Service Mode (Must turn key off to exit
service mode)
◦ Example:
− Batt 36.839V
− Pedal 2.58V Neutral
– 2 Battery Level
◦ Example:
− 2 Sealed (gel)
− 37.710 V
− Level 5
– 3 Solution Reading
◦ Example:
− Reading 0x67
− Level 3
– 4 Fault Detection
◦ 1 Enabled
◦ 2 Disabled
– 5 About (Displays the main controller software
ID)
◦ Example:
− CS7000
− 56510353_Rev_F
– 6 Shaker Continuous
◦ 1 No
◦ 2 Yes
– 7 Actuator Sequence (For engineering use)
– 8 Panel Test - Used to test each control panel
switch input. Pressing a switch while in the
Panel test will result in a corresponding
LED(S) to illuminate in response to the switch
input. If there is no response, it means the
switch is not working.
◦ Scrub Functions
− Scrub ON/OFF switch : Turn on Light
Scrub LED1
− Scrub Pressure Increase (+) switch: Turn
on Medium Scrub LED2
− Scrub Pressure Decrease (-) switch: Turn
on Heavy Scrub LED3
− Vacuum/Wand switch: Turn On Vacuum
LED
− Solution ON/OFF switch: Turn on Light
Solution LED1
− Solution Flow Increase (+)switch: Turn
on Medium Solution LED2
− Solution Flow Decrease (-) switch: Turn
on Heavy Solution LED3
◦ Sweep Functions
− Side Broom ON/OFF switch: Turn on
Side Broom LED
− Main Broom ON/OFF switch: Turn on
Main Broom LED
− Broom Mode switch: Turn ON Main
Broom LED and Side Broom LED
− Broom Up switch: Turn On Main Broom
Float LED and Dust Control LED
− Broom Down switch; Turn ON Dust Fan
LED and Shaker LED
− Broom Float Switch: Turn ON Broom
Float LED.
− Shaker switch: Turn On Shaker LED
− Dust Guard switch: Turn On Dust Guard
LED
− Dust Control switch: Turn On Dust
Control LED
◦ Hopper Functions
− Raise Hopper switch: Turn Caution LED
− Lower Hopper switch: Turn ON Warning
LED.
− Open Dump Door switch: Turn On all 3
scrub LEDs
− Close Dump Door switch: Turn On All 5
Solution LEDs
◦ Options/Accessories
− AXP ON/OFF switch: Turn On AXP LED