APA-Module Components The APA-Module LU 6.2 Connection
A29247-X2-X-8-7670 27
LU62Status Display Area
The LU62Status display informs you of the current status of all defined MVS System / APA-
Module transfer channels in a table. Each line stands for a host LU. A double click on a line
opens a detailed window of the selected connection with all possible information. The list
below explains the attributes shown in the status display and their possible values.
Status This attribute informs you of the status of the APA-Module ID Server
component, which receives the print data from the MVS system and di-
rects it to the APA-Module spool system.
The attribute can have the following values:
closed No print data is being transferred to the APA-Module
print server. No ID Server task exists.
inactive The MVS host has requested a connection with the
APA-Module system. The ID Server task has been
started, but is not yet active and the connection has
not yet been established.
init The ID Server task has initialized correctly and the
connection to the host has been established.
waitstream The ID Server task is waiting for print job data from
the MVS system
or active The ID Server task has a connection with the MVS
host.
If the printer symbol is shown, it’s receiving print data.
wait ps The ID Server task has received print job data from
the MVS system and is now waiting for it to be pro-
cessed by the PS system.
error The ID Server task has an error condition.
halted The ID Server task was unable to perform error recov-
ery and restart. The task is awaiting termination.
reset Reset ID Spool is active