4. Part Replacement
4.2.3.15 MPT Assy/MPT hopping roller/Separator/Pickup roller
(1) Remove the paper cassette.
(2) Open the MPT Assy
and remove the right and left stays by bending them
outside, and remove the MPT Assy
by sliding it to the right.
(3) Remove the MPT from the MPT Assy .
(4) Raise the pickup device upward and slide the feed paper roller
to the left and
remove it by bending the claws.
(5) R
otate the separator
centering around its pivot and remove the pivots at the two
locations. Remove the separator
and the two springs .
(6) Remove the pickup roller by bending the side surface of the frame.
Stay