43967002TH Rev.1
224 /
Oki Data CONFIDENTIAL
5. Maintenance Menu
5.6.4 Scan position adjustment
5.6.4.1 Side registration adjustment
The separate setting items are prepared for FBS, ADF (front side) and ADF (back side)
independently.
Setting for FBS
Value Default Reference value Display condition
+25 0 -25
(+5.29mm
0
-5.29mm)
-10
(-2.117mm)
±1.2mm None
Perform adjustment so that the scan start position in the horizontal scanning direction during
FBS scanning stays within the reference value.
Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.
When a value is added in the negative (-) direction, the scan image on a PC moves to the right.
When a value is added in the positive (+) direction, the scan image on a PC moves to the left.
Setting for ADF (front side)
Value Default Reference value Display condition
+25 0 -25
(+5.29mm
0
-5.29mm)
+1
(+0.2117mm)
±1.8mm None
Perform adjustment so that the scan start position in the horizontal scanning direction during
ADF front side scanning stays within the reference value.
Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.
When a value is added in the negative (-) direction, the scan image on a PC moves to the left.
When a value is added in the positive (+) direction, the scan image on a PC moves to the right.
Setting for ADF (rear side)
Value Default Reference value Display condition
+25 0 -25
(+5.29mm
0
-5.29mm)
+18
(+3.8106mm)
±2.3mm None
Perform adjustment so that the scan start position in the horizontal scanning direction during
ADF rear side scanning stays within the reference value.
Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.
When a value is added in the negative (-) direction, the scan image on a PC moves to the left.
When a value is added in the positive (+) direction, the scan image on a PC moves to the right.
5.6.4.2 Top end position adjustment
The separate setting items are prepared for FBS, ADF (front side) and ADF (back side)
independently.
Setting for FBS
Value Default Reference value Display condition
+31 0 -31
(+4.36mm
0
-4.36mm)
+8
(+1.1264mm)
±1.2mm None
Perform adjustment so that the scan start position in the vertical scanning direction during FBS
scanning stays within the reference value.
If shade is scanned at the top end of a document, make adjustment in the positive direction. If
deficiency occurs at the top end of a document, make adjustment in the negative direction.
Adjustment in increment of 1 item (0.1408 mm) is possible in this setting.
When a value is added in the negative (-) direction, the scan image on a PC moves down.
When a value is added in the positive (+) direction, the scan image on a PC moves up.

Table of Contents

Other manuals for Oki MC860

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki MC860 and is the answer not in the manual?

Oki MC860 Specifications

Printing Specifications IconPrinting Specifications
print speed color26 ppm
print speed black & white33 ppm
time to first page color10 seconds
time to first page black & white9.5 seconds
print resolution1200 x 600 dpi
processor500 MHz PowerPC CPU
duty cycle75, 000 prints per month
Copying Specifications IconCopying Specifications
copy speed color26 cpm
copy speed black & white33 cpm
first copy out color14.5 seconds
first copy out black & white13 seconds
copy resolution600 x 600 dpi
Scanning Specifications IconScanning Specifications
scan typeColor and black & white
max scan area11" x 17"
scan speed black & white33 spm
scan speed color26 spm
scan resolution600 dpi
Fax Specifications IconFax Specifications
fax modem33.6 Kbps Super G3
transmission speed2 seconds/page
fax resolution600 x 600 dpi
speed dial locations500 locations
broadcast transmission locations530 locations
Power and Acoustic Noise IconPower and Acoustic Noise
power consumption peak1, 300W
power consumption standby160W Avg.
power save mode≤25W
acoustic noise operating54dB
acoustic noise standby≤37dB
System Memory IconSystem Memory
standard imaging RAM512 MB
max imaging RAM768 MB
hard disk drive40 GB
Weight and Dimensions IconWeight and Dimensions
1-tray configuration dimensions22.2" x 25.9" x 26.3"
2-tray configuration dimensions33.3" x 30.2" x 44.5"
weight 1-tray configuration149.9 lb
weight 2-tray configuration200.6 lb
weight 3-tray configuration211.6 lb

Related product manuals