64
Chapter2 Muting
F3SG-R
User’s Manual
System Operation and Functions
Timing chart
Variable Variable name Value Description
T
1max Muting input time limit value
(maximum)
3 s Maximum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is larger
than this value, a muting error occurs.
T
2 Muting time limit 60 s The duration time of the Muting function. The Muting state is
cancelled if it continues for longer than this time limit.
T
3 Maximum allowable muting
signal interruption
0.1 s Maximum duration of a signal interruption allowed in muting
inputs A and B.
Muting input A
(Limit switch1)
ON
OFF
Muting input B
(Limit switch2)
Beam state
Unblocked
Blocked
OSSD
ON
OFF
ON
OFF
Enabled
Disabled
Auxiliary output
Blinking
OFF
T1max
Muting state
T2 max.
T2 max.
80 ms max.
Blinking at 0.5 s (1 Hz)
T3 (0.1 s) max.
T3 (0.1 s) max.