A - 107
Appendices
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
A-4 Sysmac Error Status Codes
A
A-4-1 Error List
48080000 FPGA WDT Error An FPGA error was
detected.
False detection due to a
data read error that was
caused by excessive noise
Hardware failure
P. A-15 2
64E30000 Drive Prohibition
Input Error
Both the Positive Drive Pro-
hibition (POT) and the Neg-
ative Drive Prohibition Input
(NOT) turned ON.
An error occurred on the
switch, wire, power supply,
and wiring that were con-
nected to the Positive Drive
Prohibition (POT) or Nega-
tive Drive Prohibition Input
(NOT)
False detection occurred
because the control signal
power supply was turned
ON slowly
P. A-15 3
68200000 Drive Prohibition
Detected
The operation was stopped
according to the user setting
because the motor ran in
the prohibited direction
when the Drive Prohibition
was enabled.
Incorrect or broken wiring of
Positive Drive Prohibition
Input (POT) or Negative
Drive Prohibition Input
(NOT)
Incorrect setting of the Drive
Prohibition Input
P. A-15 4
68210000 Control Right
Release Error
Communications between
the Sysmac Studio and
Servo Drive were inter-
rupted while a specific func-
tion was used from the
Sysmac Studio.
The USB cable or EtherCAT
cable was disconnected
during the connection with
the Sysmac Studio
There is excessive noise
A command sent from the
Sysmac Studio was not sent
to the Servo Drive because
the computer was in a busy
state or the like
P. A-15 5
68220000 Error Stop Input The Error Stop Input
(ESTP) is active.
The Error Stop Input
(ESTP) was input
The Error Stop Input
(ESTP) is incorrectly wired
P. A-15 6
68230000 Software Limit
Exceeded
The Position actual value
detected the position that
exceeded the value set in
the Software Position Limit,
and stopped the operation
according to the user set-
ting.
Incorrect setting of Software
Position Limit
When the Software Posi-
tion Limit - Stop Selection
was set to Stop according to
the setting of Fault reaction
option code, the position
exceeded the value set in
the Software Position Limit
P. A-15 6
78200000 Pulse Output Over-
speed Error
The speed, which exceeded
the frequency that could be
output by the Encoder
Dividing Pulse Output func-
tion, was detected.
The dividing ratio setting is
inappropriate for the actual
usage condition P. A - 157
Event code
(hex)
Event name Description Assumed cause
Level
Refer-
ence
Min
Obs
Info

Table of Contents

Other manuals for Omron R88D-1SN ECT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-1SN ECT Series and is the answer not in the manual?

Omron R88D-1SN ECT Series Specifications

General IconGeneral
FeedbackIncremental encoder, Absolute encoder
Position ControlYes
Speed ControlYes
Torque ControlYes
Communication InterfaceEtherCAT
Power Supply Voltage200 to 240 VAC
Output Power0.1 to 1.5 kW
Input Voltage Range170 to 264 VAC
Control MethodSine-wave PWM control
Main Circuit Power Supply200-240 VAC
Applicable Motor Capacity0.1 to 1.5 kW
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Encoder Error
Ambient Operating Temperature0 to 55°C
Vibration Resistance4.9 m/s² (10 to 55 Hz)
Shock Resistance98 m/s2
WeightVaries by model