Useful Functions for Operation
112
Vision System FH/FZ5 Series
User’s Manual (Z340)
Changing Regions as a Batch [Shift area]
Figure data for multiple processing items can be changed as a batch.
1 In the edit flow window, click the [Shift
area] button.
The [Shift area] dialog box is displayed.
2 Select the processing item in which to
change the region.
Only image setting processing items included
in [Input image] and [Compensate image] are
displayed.
3 Select the registration region to change.
4 Click [Move] and input the value or click
the arrows to move the image.
Images can also be directly dragged to move
them.
5 Click [OK].
The change is registered.
Monitoring Measurement Value Trends
By monitoring the trends in measurement values, the occurrence of defects can be prevented in advance and
this information can also be helpful in NG error occurrence cause analysis. Use the [Trend Monitor] processing
item to monitor the measurement values.
Refer to Trend Monitor in the Vision System FH/FZ5 Series Processing Item Function Reference Manual (Cat
No. Z341).
Judgment lower limit
Judgment upper limit
Warning (Upper limit)
Warning (Lower limit)
NG
NG
Warning occurs.
Warning occurs.
?