Page #227 background imageLoading...
Page #227 background image
WWW.NNC.IR
Basic Knowledge For Macro Customize
Functions
225
5
Optimizing Scenes (Measurement Flows) (Macro Customize
Functions)
Vision System FH/FZ5 Series
User’s Manual (Z340)
Scope of Data and Save Area
In macro customize functions, many types of data can be used as needed for the objective, and variables and
macro functions can be used to set and acquire data.
The areas where data settings and acquisition can be executed and the areas where data are saved vary
depending on the type of data.
By using data types appropriately for the objective of the program, macro customize functions enable the
creation of programs that are easy to change and maintain.
Data Scope
The locations from which data can be set and acquired are limited; data cannot be set or acquired from any
location. This limited location is called a "scope", and data can only be set and acquired from within the scope
defined for that data type.
Data scopes that can be used with the macro customize functions are as follows.
Necessity of referring
to this manual
Unit Macro
Communication
Command Macro
Scene Control
Macro
Unit Calculation
Macro
As needed
Scope Description
Within a processing unit
Within a communication command
macro
Only enabled within one processing unit.
If multiple processing units of the "Unit Macro" processing item or the "Unit
Calculation Macro" processing item are included in the measurement flow,
variables with the same name that exist in the processing units will be treated
as separate variables.
If multiple communication command macros are defined in the
communication command macro tool, variables with the same name that exist
in the communication command macros will be treated as separate variables.
Within a scene
Enabled within one scene.
If multiple processing units of the "Unit Macro" processing item or the "Unit
Calculation Macro" processing item are included in the measurement flow, the
same data can be set and acquired from each processing unit.
The data cannot be set or acquired from the processing unit of a different
scene.
Within the system
Enabled with the system.
If multiple processing units of the "Unit Macro" processing item or the "Unit
Calculation Macro" processing item are included in the measurement flow, the
same data can be set and acquired from each processing unit.
If multiple communication command macros are defined in the
communication command macro tool, the same data can be set and acquired
from each communication command macro.
The data can be set and acquired from all scene groups and scenes.

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals