Setting the Operation Mode
269
7
Changing the System Environment
Vision System FH/FZ5 Series
User’s Manual (Z340)
Single-line High-speed Mode
You can execute the measurement process with a multi-core CPU to inspect more measurement targets in the
same amount of time than conventional processing would allow. This Single-line High-speed Mode uses up to
four CPU cores (or eight threads) on a CPU that take turns in the execution of a single inspection flow every time
the STEP signal is input. This improves the performance of the conventional multi-input function. Executing the
parallel processing function on the CPU will reduce the shortest takt time by up to 1/4.
Reference: Multi-input Function (p.270)
The transaction time for a single workpiece is shorter if parallel processing is enabled to allow parallel execution of the
measurement flow.
Reference: Parallel Processing (p.282)
It is assumed that the [Single-line High-speed mode] will be used together with the multi-input function. Refer to Multi-
input Function before you use the Single-line High-speed Mode. When the multi-input function cannot be used, the
Single-line High-speed Mode is not available. Choose another mode than the Single-line High-speed Mode.
Reference: Multi-input Function (p.270)
Certain processing items, such as Serial Output, Parallel Output, and Parallel Judgement Output, may slow the
performance of the Single-line High-speed Mode if they are programmed in the first half of the flow. If the performance
drops significantly, consider the use of parallel processing.
Some processing items, such as Trend Monitor and Last NG Display, may not function correctly if Single-line High-speed
Mode is used. Do not use them. Calculation items that use the numeric values from a previous STEP may not calculate
correctly.
You cannot use Simplified Non-stop Adjustment Mode during Single-line High-speed Mode.
External commands to obtain and set unit data will not operate correctly. Do not use them.
If you use external commands, the BUSY signal will remain ON during command execution longer than for other
operation modes.