WWW.NNC.IR
Basic Knowledge For Macro Customize Functions
192
Vision System FH/FZ5 Series
User’s Manual (Z340)
Components of the Setting Screen of the Communication Command Macro Tool and How to Configure Settings
The components of the setting screen of the communication command macro tool are indicated below.
Setting Procedure for Communication Command Macro
You can create and edit communication command macros.
You can create up to 256 (from 0 to 255) communication command macros.
Descriptions of Dialog Box Objects
No. Name Description
0 Copy Copy the selected command in the command list.
1Paste
The selected command is overwritten by the copied information.
Paste targets are "comments" and "processing details." If nothing is copied, this is disabled.
2 Clear
The information of selected command, such as "Command name" "Function Name"
"Comment" and "Program" is initialized.
3 Initialization
The information of all of the commands, such as "Command name" "Function Name"
"Comment" and "Program" is initialized.
4 Command list Display the list of the commands.
5 Edit Launch the Macro program editor for selected command.
6 Enable/Disable
Set/display whether custom command is enabled.
If defined but not checked, it is not executed.
7 Command name Display and edit command name for selected command.
8 Function name Display and edit function name for selected command.
9 Comment Display and edit comment for selected command.
10 Busy On
Set/display whether to change to measurement stop state (MeasureStop) before executing
command. If checked, BUSY is turned ON while command is executing, and then after
execution of command has finished, measurement stop state is released (MeasureStart).
Afterwards, a MeasureInit event is raised.
11 Export Export the macro program to file.
12 Import
Import the macro program from file.
The existing data will be overwritten.
13 OK Save change and return to Main window.
14 Cancel Return to Main window without saving.
6
11 12 13 14
7
8
9
10
4
5
3
2
1
0