Saving Scene Groups in External Memory
169
4
Using Tools
Vision System FH/FZ5 Series
User’s Manual (Z340)
3 Set each item in the [External memory device settings] area.
4 Click [OK].
The scene group storage location is changed, and the current scene group data is transferred from the
current storage location to the new storage location. An error message is displayed if the transfer fails.
Variable name Set value [Factory default] Content
External memory
device settings
---
This setting is valid when [Save all scene group data in the
external memory device] or [Save after the next scene
group data in the external memory device] is selected for
[Scene Group Saving Destination Setting].
Used to set the storage location folder.
An error message is displayed if scene group data storage or reading fails. See ”Error Messages and Troubleshooting” in
the Appendices for descriptions of error messages.
Reference: Error Messages and Troubleshooting (p.827)
When the scene group data storage location setting is changed, a file with the [*.scg] file extension is created at the new
storage location. Do not change the file name or file extension of this scg file. If you change, the setting will not be saved
or read correctly.
You can check the available capacity of external memory in the setting screen. We recommend that you check whether
your external memory has enough available capacity before changing the storage location.
Clicking [Restore the defaults] restores the settings to their factory default values. There are different factory default
settings for the FZ5-L35@/6@@ and the FH/FZ5-11@@.
FZ5-L35@/6@@: Scene group 0 is stored in the Sensor Controller's flash memory; scene groups 1 and after are stored in
external memory.
•FH/FZ5-11@@: Scene group 0, and scene groups 1 and after are stored in the Sensor Controller's flash memory.
IMPORTANT
Note

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals