Basic Knowledge For Macro Customize Functions
188
Vision System FH/FZ5 Series
User’s Manual (Z340)
Judgement Condition Settings (Unit Calculation Macro)
1 Set judgement conditions in the
"Settings" area.
2 Select whether or not to reflect the
judgement result in the scene overall
judgement in "Reflect to overall
judgement" area.
Key Points for Test Measurement and Adjustment (Unit Calculation Macro)
To increase the speed and precision of measurement, you can adjust the parameters by performing and
checking the results of test measurements.
The following content is displayed in the "Detail result" area as text.
The image specified in the sub image in image display setting is displayed in the image display area.
Key Points for Adjustment
Select the adjustment method referring to the following points.
An error message appears on the console
Setting item
Setting value
[Factory default]
Description
Comment -
Enter a comment on the calculation processing you have selected from
the list.
Judgement
condition
• [Value judge]
• Calculation judge
Select whether to use a figure or macro judgement for the calculation result.
If figure judgement selected, set the upper/lower limits of OK judgement.
If macro judgement is selected, click [Edit] and define the calculation
processing to be performed on the calculated value.
Setting item
Setting value
[Factory default]
Description
Reflect to overall
judgement
•[ON]
•OFF
Specify whether or not the judgement results of this processing unit is
reflected in the scene overall judgement.
Displayed items Description
Judge Judgement result
Calculation 0 comment Calculation 0 value
Calculation 1 comment Calculation 1 value
::
Calculation 31 comment Calculation 31 value
Sub image. Explanation of image to be displayed
0 Measurement image
Parameter to be adjusted Troubleshooting
-
Refer to the error messages list.
Reference: X"Appendixes About Macro Functions List of Macro Error Messages" in the
"Vision System FH/FZ5 Series User's Manual (Z340)"

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals