Page #409 background imageLoading...
Page #409 background image
WWW.NNC.IR
Macro Reference
407
8
Appendices
Vision System FH/FZ5 Series
User’s Manual (Z340)
AddSystemData
Adds the system data.
Format
AddSystemData <dataIdent0>, <dataIdent1>, <data>
Parameter
Return value
None.
Description
Adds the data of identification information 1 specified in the <dataIdent1> parameter, which belongs to
identification information 0 specified in the <datdaIdent0> parameter, to the system data, and sets the value
specified in the <data> parameter in the added data.
If an identification name other than "PanDA" is specified in the <datadent0> parameter, an "Illegal function
call" error will occur.
If the system data of identification information 1 that belongs to the specified identification information 0 is
already registered, no action is taken and the process ends.
If an incorrect data type is specified for a parameter, a "Type mismatch" error will occur.
If an identification name that does not exist is specified in the <dataIdent0> parameter, an "Illegal function
call" error will occur.
If a character string longer than 255 characters is specified in the <dataIdent1> parameter, a "String too long"
error will occur.
If the format is written incorrectly, such as writing the macro function name incorrectly, omitting a comma, or
omitting a half-width space, a "Syntax error" error will occur.
Usage Cautions
• None.
Example
Adds the data of identification information 1, "LoggingCount", to the system data of identification information
0, "PanDA". Sets 20 for the setting data.
Parameter
name
Data type Description
<dataIdent0>
Character
string type
Data identification name of identification information 0 of system data to be added
(specify "PanDA")
<dataIdent1>
Character
string type
Data identification name of identification information 1 of system data to be added
<data>
Integer type
Double
precision real
number data
type
Character
string type
Value of the system data to add
AddSystemData "PanDA", "LoggingCount", 20

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals