Macro Reference
552
Vision System FH/FZ5 Series
User’s Manual (Z340)
GetUnitData
Gets the data of a processing unit.
Format
GetUnitData <unitNo>, <dataNo>, <data>
GetUnitData <unitNo>, <dataIdent>, <data>
Parameter
Return value
None.
Description
Gets the data of the external reference data number specified in the <dataNo> parameter, held by the
processing unit specified in the <unitNo> parameter. In the <data> parameter, specify the variable that will
store the gotten data.
The data can also be gotten by specifying the <dataIdent> parameter instead of the <dataNo> parameter.
If an incorrect data type is specified for a parameter, a "Type mismatch" error will occur.
If a non-existent number, numerical value, or combination of data types or values is specified for a parameter,
an "Illegal function call" error will occur.
If the format is written incorrectly, such as writing the macro function name incorrectly, omitting a comma, or
omitting a half-width space, a "Syntax error" error will occur.
Usage Cautions
• None.
Example
Gets the judgement result of the processing unit of Processing Unit number 2. The judgement result is
external reference data number 0 and external reference data identification name "JG".
Parameter
name
Data type Description
<unitNo> Integer type
Processing unit number (0 to (the number of registered processing units in the current
scene minus one))
<dataNo> Integer type
External reference data of the processing unit data to get (reference:
XVision System
FH/FZ5 Series Processing Item Function Reference Manual (Cat. No. Z341)"
<dataIdent>
Character
string type
Data identification name of processing unit data to be gotten.
<data>
Integer type
Double
precision real
number data
type
Character
string type
Gotten processing unit data
GetUnitData 2, 0, JUDGE&
Rem The same result can be gotten by specifying "JG" instead of 0.
GetUnitData 2, "JG", JUDGE&

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals