WWW.NNC.IR
Macro Reference
617
8
Appendices
Vision System FH/FZ5 Series
User’s Manual (Z340)
MeasureStart
Allows input of the measurement trigger.
Format
MeasureStart
Parameter
None.
Return value
None.
Description
Allows input of the measurement trigger and input of communication commands, and changes to the
measurement allowed state.
After setting the measurement prohibited state with the MeasureStop function, execute this macro function to
return to the measurement allowed state.
After executing the MeasureStart function, be sure to execute the MeasureStop function. If the MeasureStop
function is not executed or the MeasureStart function is executed without executing the MeasureStop
function, unexpected operation may occur.
There are macro functions that can and cannot be executed in the measurement allowed state and in the
measurement prohibited state. For details, refer to the explanations of the macro functions and usage
cautions.
If input of the measurement trigger is allowed, measurement-in-progress signals such as the BUSY signal
turn OFF.
Usage Cautions
• Execute this macro function when the BUSY signal or other measurement in progress signal is ON and
measurement is prohibited. (Reference: XState Transitions and Execution Timing (p.227))