Macro Reference
669
8
Appendices
Vision System FH/FZ5 Series
User’s Manual (Z340)
SaveBackupData
Saves the system + scene group 0 data.
Format
SaveBackupData(<fileName>)
Parameter
Return value
None.
Description
Saves the system + scene group 0 in the file with the file name specified in the <fileName> parameter.
In the <fileName> parameter, use an absolute path to specify the file name of the file to be saved.
Specify the file extension ".bkd" in the file name specified in the <fileName> parameter.
If the file specified in the <fileName> parameter already exists, it is overwritten.
If an incorrect data type is specified for a parameter, a "Type mismatch" error will occur.
If a character string longer than 255 characters is specified for a character string parameter, a "String too
long" error will occur.
If the format is written incorrectly, such as writing the macro function name incorrectly, omitting a comma, or
omitting a half-width space, a "Syntax error" error will occur.
Usage Cautions
Execute this macro function when the BUSY signal or other measurement in progress signal is ON and
measurement is prohibited. (Reference: XState Transitions and Execution Timing (p.227))
Example
Saves the system + scene group 0 data to a file.
Useable Modules
Scene Control Macro / Communication Command Macro
Supported Versions
Version 3.50 or later
Related Items
Parameter
name
Data type Description
<fileName>
Character
string type
File name of bkd file to save (system + scene group 0 data (*.bkd))
Rem Save the system + scene group 0 data to a file.
SaveBackupData "C:\BACKDIR/BackupData.bkd"
GetSystemData (Reference: X Details (p.546)) LoadBackupData (Reference: X Details (p.599))
SaveData (Reference: X Details (p.670)) SaveScene (Reference: X Details (p.675))
SaveSceneGroup (Reference: X Details (p.677)) SaveSystemData (Reference: X Details (p.679))
SaveUnitData (Reference: X Details (p.681))