Page #786 background image
WWW.NNC.IR
Macro Reference
784
Vision System FH/FZ5 Series
User’s Manual (Z340)
UnitInfo
Gets the processing unit information.
Format
UnitInfo(<unitNo>, <kind>)
Parameter
Parameter
name
Data type Description
<unitNo> Integer type
Processing unit number (0 to (number of processing units of current scene minus one)) of
the processing unit whose information is to be gotten.
<kind> Integer type
Type of information
0: Processing item type
Number that indicates the processing item type. The values below can be gotten.
0: Inspect and Measure (measurement)
1: Input image (Image input)
2: Compensate image (image correction)
3: Support Inspection and Measurement (supplementary measurement)
4: Branch (branch control)
5: Output result (result output)
6: Display result (result display)
1: Setting data structure size
Size of setting data structure. Units are bytes.
2: Measurement data structure size
Size of measurement data structure. Units are bytes.
3: Control data structure size
Size of control data structure. Units are bytes.
4: The maximum number of figure data
Maximum number of figure data items held by processing unit.
5: Maximum number of model data
Maximum number of model data items held by processing unit.
6: Maximum number of image data
Maximum number of image data items held by processing unit.
7: Maximum number of inner processing unit
Maximum number of processing units held (incorporated) by processing unit.
8: Whether camera setting is effective or not
Displays whether or not the processing unit updates the camera settings at
measurement initialization and other times. "1" is returned when there is an image input
processing unit for camera image input.
0: Camera settings invalid
1: Camera settings valid
9: Whether processing unit measure processing can parallel or not
Displays whether or not parallel execution of processing units is possible in the
measurement flow during measurement. "1" is returned when the processing units
support parallel processing.
0: Parallel processing disabled
1: Parallel processing enabled
For the parallel processing, refer to Parallel Processing. (Reference: XParallel
Processing (p.282))

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals