5-74 Menus and Commands
6-00054-02 Rev A
Target ID Dialog
Path: Main Menu Setup Menu Library
Submenu SCSI Submenu Target ID Dialog
Use the Target ID Dialog to set the library SCSI ID.
Changes will not take effect until library power is cycled.
See Figure 5-101.
Figure 5-101 Target ID Dialog
Parameter Value
Bus 0: Next Next indicates the SCSI ID
address that takes effect for
bus port 0 after power is cycled
(0–7).
Bus 0: Now Now indicates the SCSI ID
address that is currently in
effect (0–7) for bus port 0.
Bus 1: Next Next indicates the SCSI ID
address that takes effect for
bus port 1 after power is cycled
(0–7).
Bus 1: Now Now indicates the SCSI ID
address that is currently in
effect (0–7) for bus port 1.
Accept Y to accept changes
N to reject changes
If Y is selected for the Accept parameter value, the screen
updates to reflect the changes. Otherwise, the changed
parameters continue to display but no action is taken.
Note
The Scalar 1000
defaults to SCSI
ID 6.
Target ID: Next Now
Bus 0: 4< 4
Bus 1: 4 4
Accept: N