Restarting the Scalar 1000 4-11
22 June 2004
Restarting the Scalar 1000
Use the following procedure to restart the Scalar 1000.
Power up must be delayed by one minute after a power
down condition to allow the RMU to properly reset.
Step 1 If applicable, correct any situations that required
the Scalar 1000 shutdown.
Step 2 Refer to Starting the Scalar 1000 on page 4-7 for
instructions on the Scalar 1000 start procedure.
Using the Remote Management Unit
The Remote Management Unit (RMU) is a component in the
library that provides remote access to the library by means of
a Web browser. All functions listed here are available without
the need of a dedicated server (or separate software).
The RMU performs the following functions:
• Provides remote operation of all library Operator Panel
functions by means of a Web browser.
• Allows you to check the status of the system, firmware
levels, and other useful information.
• Updates RMU firmware.
• Supports Simple Network Management Protocol (SNMP)
version 2.0 and acts as an SNMP-server, generating SNMP
traps and responding to SNMP requests.
• Supports ADIC Library Management Information Base
(MIB) version 2.0.
• Acquires Tape Alert 3.0 information from the library and
sends that information to an SNMP manager.
• Detects a power loss and generates an SNMP trap for
notification.
• Enables the retrieval of library logs, and drive and RMU
diagnostic files.
• Allows RMU configuration changes such as network,
users, and date/time.
• Provides online access to documentation.