Setup Menu 5-89
22 June 2004  
Advanced Dialog
Path: Main Menu Setup Menu Advanced Dialog
Use the Advanced Dialog to enable or disable the 
automatic configuration, calibration, or cartridge scan when 
the library power has been cycled. See Figure 5-119. 
If Auto Inventory is disabled, the element status is not 
known until the host issues an Initialize Element Status 
command or an Inventory is performed via the Operator 
Panel. 
If Auto Inventory is enabled, an automatic cartridge 
inventory is executed on each power cycle.
Any changes in the Operating Mode parameter value should 
be made by authorized Service Personnel. 
The default is set to 02.
Figure 5-119 Advanced Dialog
Parameter Value
Auto Teach Y to enable Auto Teach for 
automatic configuration and 
calibration on each power 
cycle
N to disable Auto Teach on 
each power cycle
Auto Inventory Y to enable Auto Inventory for 
automatic cartridge scanning 
inventory on each power cycle
N to disable Auto Inventory on 
each power cycle
Operating Mode 0 to select no library initiated 
UNLOAD command before a 
move.
1 to select a three second delay 
before a Get operation is 
performed on a SDLT/DLT 
drive after detecting that a tape 
Auto Teach : Y<
Auto Inventory: Y 
Operating Mode: 02
Accept: N