Enabling Library AutoClean 6-23
22 June 2004  
 
Enabling Library AutoClean 
The host should not share Scalar 1000 controlled cleaning 
media. If a host uses the Scalar 1000 firmware controlled 
cleaning media, the Scalar 1000 firmware will not update 
cleaning media usage information. 
Use this procedure to set autoclean. For further information, 
refer to Drives Dialog  on page 5-93.
Path: Setup Menu Cleaning Submenu
Step 1 Follow the path and the Cleaning Submenu 
appears. See Figure 6-3.
Figure 6-3 Cleaning Submenu
Step 2 Select Drives and the AutoClean dialog appears. 
See Figure 6-4.
Figure 6-4 AutoClean Dialog
Step 3 Select AutoClean, set the schedule (immediate or 
delayed), Hours, Min (time to start the cleaning), 
Accept.
Immediate - every dismount causes the firmware to 
check for a cleaning request from the drive. If the 
firmware receives a clean drive request, the drive is 
cleaned immediately, and the tape move complete 
response is delayed until the cleaning process is 
complete. 
>Drives...
Media...
View...
AutoClean:  Y<
Schedule: Delayed
Hours: 00Min :00
Accept:: N