CALCulate<n>:LIMit<li>:ACTive?
This command queries the names of all active limit lines.
Suffix:
<n>
.
irrelevant
<li> irrelevant
Return values:
<LimitLines> String containing the names of all active limit lines in alphabeti-
cal order.
Example:
CALC:LIM:ACT?
Queries the names of all active limit lines.
Usage: Query only
Manual operation: See " Visibility " on page 476
CALCulate<n>:LIMit<li>:COPY
<Line>
This command copies a limit line.
Suffix:
<n>
.
Window
<li> Limit line
Parameters:
<Line> 1 to 8
number of the new limit line
<name>
String containing the name of the limit line.
Example:
CALC:LIM1:COPY 2
Copies limit line 1 to line 2.
CALC:LIM1:COPY 'FM2'
Copies limit line 1 to a new line named FM2.
Manual operation: See " Copy Line " on page 477
CALCulate<n>:LIMit<li>:DELete
This command deletes a limit line.
Suffix:
<n>
.
Window
<li> Limit line
Manual operation: See " Delete Line " on page 477
CALCulate<n>:LIMit<li>:STATe <State>
This command turns the limit check for a specific limit line on and off.
Analyzing Measurements (Basics)