Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1052User Manual 1178.8520.02 ─ 01
Suffix:
<n>
.
irrelevant
<li> Limit line
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Manual operation: See " Visibility " on page 476
CALCulate<n>:LIMit<li>:UPPer:THReshold <Limit>
This command defines an absolute limit for limit lines with a relative scale.
The R&S FSV/A uses the threshold for the limit check, if the limit line violates the
threshold.
Suffix:
<n>
.
irrelevant
<li> Limit line
Parameters:
<Limit> Numeric value.
The unit depends on CALCulate<n>:LIMit<li>:UNIT
on page 1049.
*RST: -200
Default unit: dBm
Manual operation: See " Threshold " on page 478
Managing Limit Lines
Useful commands for managing limit lines described in the R&S FSV/A User Manual:
●
MMEM:SEL[:ITEM]:LIN:ALL
●
MMEM:STOR:TYPE
●
MMEM:LOAD:TYPE
Remote commands exclusive to managing limit lines:
CALCulate<n>:LIMit<li>:ACTive?...................................................................................1053
CALCulate<n>:LIMit<li>:COPY......................................................................................1053
CALCulate<n>:LIMit<li>:DELete.................................................................................... 1053
CALCulate<n>:LIMit<li>:STATe......................................................................................1053
CALCulate<n>:LIMit<li>:TRACe<t>:CHECk....................................................................1054
MMEMory:LOAD<n>:LIMit............................................................................................ 1055
MMEMory:STORe<n>:LIMit.......................................................................................... 1055