EasyManua.ls Logo

R&S FSV3000 Series - Page 1098

R&S FSV3000 Series
1268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1098User Manual 1178.8520.02 ─ 01
Remote commands exclusive to transducer management
[SENSe:]CORRection:TRANsducer:ADJust:RLEVel[:STATe]............................................ 1098
[SENSe:]CORRection:TRANsducer:CATalog?.................................................................1098
[SENSe:]CORRection:TRANsducer:COMMent................................................................1099
[SENSe:]CORRection:TRANsducer:DATA...................................................................... 1099
[SENSe:]CORRection:TRANsducer:DELete....................................................................1099
[SENSe:]CORRection:TRANsducer:SCALing..................................................................1100
[SENSe:]CORRection:TRANsducer:SELect.................................................................... 1100
[SENSe:]CORRection:TRANsducer[:STATe]....................................................................1100
[SENSe:]CORRection:TRANsducer:UNIT....................................................................... 1100
MMEMory:LOAD<n>:TFACtor....................................................................................... 1101
MMEMory:STORe<n>:TFACtor......................................................................................1101
[SENSe:]CORRection:TRANsducer:ADJust:RLEVel[:STATe] <State>
This command turns an automatic adjustment of the reference level to the transducer
on and off.
Before you can use the command, you have to select and turn on a transducer.
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0
Manual operation: See " Adjust Ref Level " on page 596
[SENSe:]CORRection:TRANsducer:CATalog?
This command queries all transducer factors stored on the R&S FSV/A.
After general data for the transducer storage directory, data for the individual files is lis-
ted.
The result is a comma-separated list of values with the following syntax:
<UsedMem>,<FreeMem>,<FileSize>,<FileName>[,<FileSize>,<FileName>]
Return values:
<UsedDiskSpace> numeric value in bytes
Amount of storage space required by all transducers files in the
C:\Program Files\Rohde-Schwarz\FSV3000\<version>\
trd directory (= sum of all individual <FileSize> values)
<FreeDiskSpace> numeric value in bytes
Amount of free storage space on the R&S FSV/A
<FileSize> numeric value in bytes
Size of a single transducer file
<FileName> string
Name of a single transducer file
Configuring the R&S FSV/A

Table of Contents

Other manuals for R&S FSV3000 Series

Related product manuals