EasyManua.ls Logo

R&S FSV3000 Series - Page 1142

R&S FSV3000 Series
1268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1142User Manual 1178.8520.02 ─ 01
INSTrument:COUPle:VBW <State>
This command turns synchronization of the video bandwidth between measurement
channels on and off.
Parameters:
<State> ALL | NONE
ALL | 1
Turns on synchronization.
NONE | 0
Turns off synchronization.
*RST: NONE
Example:
INST:COUP:VBW ALL
Synchronizes the video bandwidth.
14.10.11.2
User-Defined Parameter Coupling
INSTrument:COUPle:USER<uc>................................................................................... 1142
INSTrument:COUPle:USER<uc>:CHANnel:LIST?........................................................... 1144
INSTrument:COUPle:USER<uc>:ELEMent:LIST?............................................................1144
INSTrument:COUPle:USER<uc>:INFO...........................................................................1145
INSTrument:COUPle:USER<uc>:NEW?......................................................................... 1146
INSTrument:COUPle:USER<uc>:NUMBers:LIST?...........................................................1148
INSTrument:COUPle:USER<uc>:RELation..................................................................... 1148
INSTrument:COUPle:USER<uc>:REMove......................................................................1149
INSTrument:COUPle:USER<uc>:STATe......................................................................... 1149
INSTrument:COUPle:USER<uc>:WINDow:LIST?............................................................ 1149
INSTrument:COUPle:USER<uc> <ChannelName>, <Window>, <Parameter>,
<ChannelName>, <Window>, <Parameter>, <arg6>, <State>
This command edits an existing user-defined coupling definition.
The parameters for this command are identical to INSTrument:COUPle:USER<uc>:
NEW?. Note, however, that for INSTrument:COUPling:USER<uc>, the last two
parameters (<Direction> and <State>) are not optional.
Note: Make sure to specify the right index number via the USER suffix.
Suffix:
<uc>
.
Index of a user-defined parameter coupling. Which indexes are
available is defined by INSTrument:COUPle:USER<uc>:
NUMBers:LIST?.
Parameters:
<ChannelName> String containing the name of a measurement channel or chan-
nel type.
<Name>
To synchronize two specific measurement channels.
'All Spectrum'
To synchronize all spectrum channels.
Configuring the R&S FSV/A

Table of Contents

Other manuals for R&S FSV3000 Series