EasyManua.ls Logo

R&S FSV3000 Series - Page 1147

R&S FSV3000 Series
1268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1147User Manual 1178.8520.02 ─ 01
Optional: Selects the direction in which synchronization works.
BIDir
Changes of a parameter are applied both ways (from channel 1
to channel 2 and vice versa).
LTOR
Changes of a parameter are applied from channel 1 to channel
2, but not the other way around.
RTOL
Changes of a parameter are applied from channel 2 to channel
1, but not the other way around.
<State> ON | OFF | 0 | 1
Optional. Enables or disables coupling.
OFF | 0
Switches the coupling off
ON | 1
Switches the coupling on
*RST: 1
Return values:
<Index> Index number of the new user-defined coupling.
Note that the returned index numbers do not necessarily have to
be the same as those shown in the user interface.
Example:
INST:COUP:USER:NEW? 'Spectrum1','All
Windows','Attenuation','Spectrum2','All
Windows','Attenuation',BID,ON
Result:
3
Synchronizes the attenuation between the channels named
'Spectrum1' and 'Spectrum2' in both directions and turns on the
coupling. Also returns the index number of the user-defined cou-
pling.
Example:
INST:COUP:USER:NEW? 'All Spectrum','All
Windows','Attenuation','','','',BID,ON
Result:
3
Synchronizes the attenuation between all Spectrum channels in
both directions and turns on the coupling. Also returns the index
number of the user-defined coupling.
Usage: Query only
Manual operation: See "Parameter 1 / Parameter 2" on page 635
See "Add New User Coupling" on page 636
Configuring the R&S FSV/A

Table of Contents

Other manuals for R&S FSV3000 Series