Timer Settings
This section describes the user tools in the Timer Settings menu under System Settings.
Auto Off Timer (Type 1 and 2)
After a specified period has passed, following job completion, the machine automatically turns off,
in order to conserve energy. This function is called “Auto Off”.
The machine status after the Auto Off operation is referred to as "Off mode", or "Sleep mode".
For the Auto Off Timer, specify the time to elapse before Auto Off.
The default setting is “45” min.
The time can be set from 1 to 240 minutes, using the number keys.
Auto Off may not work when error messages appear.
Auto Off Timer (Type 3 and 4)
After a specified period has passed, following job completion, the machine automatically turns off,
in order to conserve energy. This function is called "Auto Off".
The machine status after the Auto Off operation is referred to as "Off mode", or "Sleep mode".
For the Auto Off Timer, specify the time to elapse before Auto Off.
The default setting is “60” min.
The time can be set from 1 to 240 minutes, using the number keys.
Auto Off may not work when error messages appear.
Energy Saver Timer
Set the amount of time the machine waits before switching to lower-power mode after copying has
finished or the last operation is performed.
The time can be set from 1 to 240 minutes, using the number keys.
The default setting is “15” min.
Panel Off Timer
Set the amount of time the machine waits before switching the panel off after copying has finished or
the last operation is performed.
Enter a time interval between 10 seconds and 240 minutes, using the number keys.
The default setting is “1 minute (s)”.
System Auto Reset Timer
The System Reset setting automatically switches the screen to that of the function set in Function Priority
when no operations are in progress, or when an interrupted job is cleared. This setting determines the
system reset interval.
The time can be set from 10 to 999 seconds, using the number keys.
The default setting is [On], “60” second (s).
Timer Settings
31
1

Table of Contents

Other manuals for Ricoh Aficio MP C5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio MP C5000 and is the answer not in the manual?

Ricoh Aficio MP C5000 Specifications

General IconGeneral
BrandRicoh
ModelAficio MP C5000
CategoryAll in One Printer
LanguageEnglish

Related product manuals