EasyManua.ls Logo

Ricoh D065 - Page 1118

Ricoh D065
1351 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bit Switches - 3
SM 105 D418
Fax Option
Type 9001
D418
Communication Switch 0D (SP No. 1-104-014)
No Function Comments
ringing signals and go into receive mode even if
there is no memory available. This will result in
communication failure.
Communication Switch 0E (SP No. 1-104-015)
No Function Comments
0-7
Minimum interval between
automatic dialing attempts
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine
waits before it dials the next destination.
Communication Switch 0F – Not used (do not change the settings.)
Communication Switch 10 (SP No. 1-104-017)
No Function Comments
0-7
Memory transmission:
Maximum number of dialing
attempts to the same
destination
01 – FE (Hex) times
Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 (SP No. 1-104-019)
No Function Comments
0-7
Memory transmission: Interval
between dialing attempts to the
01 – FF (Hex) minutes

Table of Contents