Service Call Conditions
SM Appendix 3-43 D062/D063/D065/D066
Appendix:
Service Call
Conditions
Finisher punch motor error
760 D
The punch HP sensor is not
activated within the specified
time after the punch motor turned
on. The 1st detection failure
issues a jam error, and the 2nd
failure issues this SC code.
Punch HP sensor disconnected,
defective
Punch motor disconnected,
defective
Punch motor overload due to
obstruction
Finisher folder plate motor error
761 B
The folder plate moves but is not
detected at the home position
within the specified time. The 1st
detection failure issues a jam
error, and the 2nd failure issues
this SC code.
Folder plate HP sensor
disconnected, defective
Folder plate motor disconnected,
defective
Folder plate motor overloaded due
to obstruction.
Punch movement motor error
763 D
Occurs during operation of the
punch unit. The 1st detection
failure issues a jam error, and the
2nd failure issues this SC code.
Motor harness disconnected, loose,
defective
Motor defective
Paper position sensor slide motor error
764 D
Occurs during operation of the
punch unit. The 1st detection
failure issues a jam error, and the
2nd failure issues this SC code.
Motor harness disconnected, loose,
defective
Motor defective