EasyManua.ls Logo

Ricoh D065 - Page 538

Ricoh D065
1351 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Program Mode Tables
SM Appendix 4-5 D062/D063/D065/D066
Appendix:
Service
Program
Mode Tables
D066: [150 to 200/185/1degree C]
009
Small Size – Normal Paper
(Center)
Fusing temperature at center of hot roller when
printing on normal paper:
D062/D063/D065: [150 to 205/190/1 degree C]
D066: [150 to 200/185/1 degree C]
010
Small Size – Thick Paper
(Center)
Fusing temperature at center of hot roller when
printing on thick paper:
D062/D063/D065: [150 to 205/190/1 degree C]
D066: [150 to 200/195/1 degree C]
1106 Fusing Temperature Display
001 Center Temperature
Shows the temperature of the hot roller detected by
the thermistor at the center of the hot roller.
002 End Temperature
Shows the temperature of the hot roller detected by
the thermistors at the ends of the hot roller.
003
Pressure Roller
Temperature
Shows the temperature of the hot roller detected by
the thermistors at the pressure roller.
1107 Start Fusing Adjustment
This SP allows you to set when to start the fusing temperature adjustment for
the center and end heating lamps.
001 Center Lamp Temperature
002 End Lamp Temperature
D062/D063/D065: [150 to 205/205/1 deg C]
D066: [150 to 190/190/1 deg C]
003 Center Lamp Actual Time
D062/D063/D065: [0 to 120/60/1 sec.]
D066: [0 to 60/10/1 sec.]
004 End Lamp Actual Time
D062/D063/D065: [0 to 120/55/1 sec]
*For Only TWN [0 to 120/60/1 sec]
D066: [0 to 60/10/1 sec]

Table of Contents

Related product manuals