Service Program Mode Tables
SM Appendix 4-69 D062/D063/D065/D066
Appendix:
Service
Program
Mode Tables
4785* White Level Peak Range G
Min: FC
001
Adjusts the lower limit threshold for the white level peak range of Green signal in
the full color mode.
[0 to 255 / 64 / 1 digit]
Max: FC
002
Adjusts the upper limit threshold for the white level peak range of Green signal
in the full color mode.
[0 to 255 / 245 / 1 digit]
Min: BK
003
Adjusts the lower limit threshold for the white level peak range of Green signal in
the B/W mode.
[0 to 255 / 64 / 1 digit]
Max: BK
004
Adjusts the upper limit threshold for the white level peak range of Green signal
in the B/W mode.
[0 to 255 / 245 / 1 digit]
4786* White Level Peak Range G
Min: FC
001
Adjusts the lower limit threshold for the white level peak range of Blue signal in
the full color mode.
[0 to 255 / 64 / 1 digit]
Max: FC
002
Adjusts the upper limit threshold for the white level peak range of Blue signal in
the full color mode.
[0 to 255 / 245 / 1 digit]
003 Min: BK