11
2017 Page 117 5IN2413 B
Zones Parameters By Category Advanced Bus Zone Parameters
Quick keys Parameter Default Range
Bus Zone Parameters
The Bus Zone Parameters menu contains parameters that enable you to
program the special parameters of a bus zone. The options are determined
according to the bus detector type:
1. Select the zone number (ZZZ) and then press OK.
2. Then scroll to select from the available BZ parameters to configure
(parameters are device-specific – see device list below).
3. Set parameters for the following RISCO bus detectors (see the following
sections as well as the packaged instructions for details), and when
finished, press OK.
RISCO Bus Detectors:
• Lunar Grade 3: A dual technology ceiling detector with a mounting
height of up to 8.6m (28ft) that incorporates Anti-Cloak
TM
Technology
(ACT).
• WatchOUT DT: A dual technology outdoor detector with signal
processing based on two Passive Infrared (PRI) channels and two
microwave (MW) channels.
• WatchOUT PIR: An outdoor detector with signal processing based on
two Passive Infrared correlated channels
• WatchIN DT Grade 3: A dual technology Grade 3 industrial detector
with signal processing based on two Passive Infrared channels and two
microwave channels.
• iWISE QUAD Grade 2: A motion detector incorporating Quad PIR
technology
• iWISE QUAD Grade 3: A motion detector incorporating Anti-Mask
and Quad PIR technologies.
• iWISE DT Grade 3: A motion detector incorporating both Anti-Mask
and Anti-Cloak
TM
Technologies (ACT). It adheres to environmentally
friendly guidelines and is available in 15m and 25m models.
• BWare DT Grade 3 A dual technology Grade 3 industrial detector with
signal processing based on two Passive Infrared channels and two
K-band microwave channels.
• BWare QUAD Grade 3 A motion detector incorporating Anti-Mask and
Quad PIR technologies.
• Seismic: A detector that monitors the vibration and temperature of a
specific surface and will react to all known types of intruder attacks.