11
/
2017 Page 116 5IN2413 B
Quick keys Parameter Default Range
1. Select the zone (ZZZ) and then press OK.
2. Then scroll to select either DISABLE or ENABLE.
3. Press OK.

Pulse Counter
01
0115
Specifies that the zone will count the number of open and close pulses
received. If the zone exceeds the predefined number of pulses, the zone
will be tripped and act according to its type definition. After a 25-second
timeout the pulse counter is restarted. The pulse length is the currently
defined loop response time period (see Zones Loop Response,
page 115).
Select the pulse count, and then press OK.

Abort Alarm
This parameter defines whether a zone alarm report to the monitoring
station will be immediate or delayed:
1. Select the zone (ZZZ) and then press OK.
2. Then scroll to select either:
ENABLE: A report to the MS will be delayed according to the
Abort Time Delay parameter
 (Communication MS
MS Times Abort Alarm
).
DISABLE: A report to the MS will be sent immediately
3.. Press OK.