11
/
2017 Page 137 5IN2413 B
Quick keys Parameter
xx 
Sensors Test
Relates to the ProSYS Plus Zone Self-Test (Quick Keys )
This option is selected if the designated utility output is part of the circuit
providing switched power for the source of noise (or vibration) used in the
sensors test procedure.
xx 
Battery Test
A pulsed utility output will follow the battery test only once a day at 9:00
AM. The pulse interval is ten seconds. This parameter is usually used to
perform an overload test on the system by using an external device.
xx 
Bell Burglary
Activates the utility output after any bell burglary alarm in any partition in
the system.
xx 
Scheduler
The utility output will follow the predefined time programming that is
defined in the scheduler of the weekly programs for utility output
activation. For additional details, refer to the ProSYS Plus User Manual.
xx 
Switched Aux
Activates the utility output when a fire zone is activated (for fire detection)
according to the time defined in double verification of fire alarms (see
Double Verification of Fire Alarms, page 85).
This utility output will not have the option to choose pulse or latch in the
Utility Output: Code. The pulse time is defined in Switch Aux Break,
page 79.
Quick keys Parameter
xx 
GSM Error
Relates to the installed GSM module. Activates the utility output in the
following cases:
There is no SIM card in the GSM module or SIM is faulty
GSM RSSI signal level is low
GSM network fault
xx 
Bell Test
Activates the output when the “Bell Test” option is selected and
deactivates when the “Bell Test” option is finished.