EasyManua.ls Logo

Risco ProSYS Plus - Page 138

Risco ProSYS Plus
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
/
2017 Page 138 5IN2413 B
Quick keys Parameter
xx 
Installation
Activates the output following the system installation status. It activates
when the system is in installer programming mode and deactivates when
exiting installer’s mode.
xx 
Walk Test
Activates the output when the “Walk Test” option is selected and
deactivates when the “Walk Test” option is finished.
xx 
Burglary
Activates the output (Pulsed only) following any intruder activation in the
system (Regardless the bell time out timer). The maximum number of
times an output can be activated from the same zone is defined according
to the Swinger Limit Timer (Quick key
)
xx 
Panic
Activates the output (Pulsed only) following any panic activation in the
system. The maximum number of times an output can be activated from
the same zone is defined according to the Swinger Limit Timer
(Quick key
).
xx 
Fire
Activates the output (Pulsed only) following any fire activation in the
system. The maximum number of times an output can be activated from
the same zone is defined according to the Swinger Limit Timer (Quick key
).
xx 
Special
Activates the output (Pulsed only) following any special emergency
activation in the system. The maximum number of times an output can be
activated from the same zone is defined according to the Swinger Limit
Timer (Quick key
).
xx 
24 Hour
Activates the output (Pulsed only) following any 24 Hour zone activation
in the system. The maximum number of times an output can be activated
from the same zone is defined according to the Swinger Limit Timer
(Quick key
).