2017 Page 140 5IN2413 B
xx
Panic Follow
Activates the utility output when a panic alarm is triggered in the
selected partition(s) from the keypads, remote controls or a zone
defined as Panic.
xx
Special Follow (Emergency)
Activates the utility output when a special alarm is triggered in the
selected partition(s) from the keypads or a zone defined as Special
.
xx
Buzzer Follow
Activates the output when a keypad in the selected partition(s) sounds its
buzzer during auto setting, Exit/Entry delays, and alarm conditions.
xx
Chime Follow
Activates the output when a keypad in the selected partition(s) sounds its
chime.
xx
Exit/Entry Follow
Activates the output when the selected partition(s) initiates an Exit/Entry
delay period.
xx
Fire Trouble Follow
Activates the output when a Fire Trouble is detected in the selected
partition(s).
xx
Day Trouble (Zone)
Activates when a day zone trouble is detected in the selected partition(s).
xx
Trouble Follow (General)
Activates the output when a fault condition is detected in the selected
partition.
xx
Stay Follow
Activates the utility output when the selected partition(s) is armed in the
partial (Stay) arming mode.
xx
Tamper Follow
A latched output activated when a tamper occurs in the selected
partition(s) and follows any type of tamper. The output deactivates at
tamper reset.
xx
Disarm Follow
Activates the utility output when the selected partition(s) is disarmed.