Bell Trigger
Mainly used for the connection of different external sounders to different
partitions in the UK. Activates the output when one of the defined
partitions is in alarm mode and the bell is triggered. It will be activated for
the programmed bell time out or until alarm is disarmed.
This output generates squawk sounds and has a special sound for fire
alarms.
ote
In fire alarm the output will not follow the bell delay time (see Bell Delay,
page 79) but will trigger immediately. It will be triggered in pulsed
sequence: five seconds on and two seconds off.
xx
Strobe Trigger
A latched output that is used to trigger a strobe. The output is activated
when one of the defined partitions is in alarm mode or during squawks.
The output will be activated until the alarm is disarmed. The output is also
activated in test mode.
ote
A tamper alarm will not activate the output if all partitions are disarmed.
xx
Fail To Arm
Activates when one of the defined partitions fails to arm and deactivates at
user reset.
xx
Confirm Alarm
The output activates when a confirmed alarm occurs in a partition and
deactivates at the restore of the alarm confirmation. RISCO recommends
using this output for the Red-Care STU Confirmed Alarm channel.
xx
Duress Follow
Activates the Utility Output when a duress alarm is initiated at the
keypad related to the selected partition(s).
xx
HU Confirmation Al. (Hold Up Confirmation Alarm)
Activates the output when "Hold-Up Alarm Confirmation" occurs in the
selected partition(s). See page 94.