2017 Page 153 5IN2413 B
Communication Method GSM
Quick Keys Parameter Default Range

GSM
The GSM screen contains parameters for the communication of the system
over the GSM/GPRS network.

Timers
Allows to program timers related to operation with the GSM module

GSM Lost
1 minute
001
255 minutes
The period length during which the reception is below the minimum
threshold (defined by the GSM Network Sensitivity parameter) that
triggers the panel to send a report of GSM Lost.
( )

GSM Network Loss
10 minutes
001
255 minutes
The period length after which the panel will send a report of GSM network
loss to the monitoring station.

SIM Expire
0 months
00
36 months
A pre-paid SIM card has a defined life length defined by the provider.
After each charging of the SIM, the user will have to manually reset the
expiration time of the SIM card. Thirty days before the expiring date, a
notification will be displayed on the keypad’s LCD.
Set the SIM expiring date (in months) using the numeric keys, according to
the time given by the provider.

MS Polling
00000
0
65535 times
The time period that the system will establish automatic communication
(polling) with the monitoring station over GPRS, in order to check the
connection.
3 polling times can be defined: Primary, Secondary and Backup. For each
time period define the number of units between 1- 65535. Each unit
represents a time frame of 10 seconds.
Notes
When using the polling feature through GPRS the MS channel
parameter must be defined as GPRS only.
The report code for MS polling is 999 (Contact ID) or ZZ (SIA)
When the GPRS Primary polling time is defined as 0, no polling
message is sent to the MS