11
2017 Page 155 5IN2413 B
MS Polling example:
When selecting MS 1 (GPRS), MS 2 (GPRS) and split report option 1
st
Backup 2
nd
(using the default primary, secondary and backup time
intervals), the report process will be as follows:
In a normal state:
Polling through the GPRS network using the GSM module will occur
every 90 seconds according to the primary time interval to MS 1 and every
3600 seconds (1 hour) according to the secondary time interval to MS 2.
When communication to MS 1 fails, polling occurs every 90 seconds
according to the backup interval to MS 2. When communication returns to
MS 1, polling reverts back to the secondary time interval and occurs every
3600 seconds (1 hour) to MS#2.
GPRS
Allows programming parameters that relate for the communication over
the GPRS network.
APN Code
To establish a connection to the GPRS network an APN (Access Point
Name) code is required. The APN code differs from country to country
and from one provider to another (the APN code is provided by your
cellular provider).
The ProSYS Plus supports an APN code field of up to 30 alphanumeric
characters and symbols (!, &, ? etc.).
APN User Name
Enter user name for the GPRS network (if required). The user name is
provided by your provider.
The ProSYS Plus supports a user name field of up to 20 alphanumeric
characters and symbols (!, &, ? etc.).
APN Password
The password to the GPRS network as provided by your provider (if
required).
The ProSYS Plus supports a user name field of up to 20 alphanumeric
characters and symbols.
Email
The following programming parameters are used to enable sending
Follow Me event messages by e-mail through GPRS.
Note
To enable e-mail messaging, the GPRS parameters have to be defined.