11
/
2017 Page 159 5IN2413 B

Email
Allows programming parameters that enable the system to send
e-mail messages following Follow Me events

Mail Host
000.000.000.000
The IP address or the host name of the SMTP mail server.

SMTP Port
00000
00000
65535
The port address of the SMTP mail server

Email Address
The e-mail address that identifies the system to the mail recipient.

SMTP Name
A name identifying the user to the SMTP mail server. Its field can include
up to 10 alphanumeric characters and symbols (!, &, ? etc.).

SMTP Password
The password authenticating the user to the SMTP mail server. It can
include up to 10 alphanumeric characters and symbols (!, &, ? etc.).

Encryption
The encryption type used for IP

Host Name
Security System Up to 32 Characters
IP address or a text name used to identify the ProSYS Plus over the
network. Default: Security System

MS Polling
(Keep Alive)
The time period that the system will establish automatic communication
(polling) with the monitoring station over the IP network, in order to check
the connection. Three polling times can be defined: primary, secondary and
backup. For each time period, define the number of units between 1– 65535.
Each unit represents a time frame of 10 seconds.
Note
When using the polling feature through IP, the MS channel parameter must
be defined as IP only.
The use of these time periods depends on the reporting order to the MS
defined by the report split MS urgent parameter (see MS Urgent, page 173).
The following table describes how the three MSs use the primary, secondary
& backup time intervals in the various MS report split options: